-- CISCO-FABRIC-C12K-MIB.my: Cisco Fabric MIB for c12000 series.
--
-- July 2002, K.Muralidhar
--
-- Copyright (c) 2002 by cisco Systems, Inc.
-- All rights reserved.
-- *****************************************************************CISCO-FABRIC-C12K-MIB DEFINITIONS::=BEGINIMPORTSCounter32,Unsigned32,MODULE-IDENTITY,OBJECT-TYPE,NOTIFICATION-TYPEFROM SNMPv2-SMI
TEXTUAL-CONVENTION,TruthValueFROM SNMPv2-TC
SnmpAdminStringFROM SNMP-FRAMEWORK-MIB
MODULE-COMPLIANCE,NOTIFICATION-GROUP,
OBJECT-GROUPFROM SNMPv2-CONF
PhysicalIndex,entPhysicalIndex,entPhysicalName
FROM ENTITY-MIB
EntPhysicalIndexOrZero
FROM CISCO-TC
ciscoMgmt
FROM CISCO-SMI;ciscoFabricC12kMIB MODULE-IDENTITYLAST-UPDATED"200209200000Z"ORGANIZATION"Cisco Systems, Inc."CONTACT-INFO" Cisco Systems
Customer Service
Postal: 170 W. Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: gsr-netman@cisco.com"DESCRIPTION"Cisco Fabric MIB module for c12000 series of routers.
This MIB module is used for managing/tracking the c12000
fabric entities and fabric related configuration, status
and statistics information.
C12000 fabric architecture is based on NxN non-blocking
crossbar switch fabric, where N stands for the maximum
number of LCs that can be supported in the chassis (this
includes the RP). The connections through the switch
fabric is controlled by a scheduler (CSC), the CSC
accepts transmission requests from line cards, issues
grants to access the fabric, and provides a reference
clock to all the cards in the system to synchronize data
transfer across the crossbar.
Some of the error status objects in the MIB are read-clear,
that is the value of the object is cleared on a query of the
object.
Details about the various fabric related attributes
specified in the MIB could be found at following link,
http://www.cisco.com/warp/public/108/hwts_12000_22281.html
Acronyms and terms used in the MIB module:
GSR - Gigabit Switch Router.
RP - Route Processor.
LC - Line Card.
SFC - Switch Fabric Card.
CRC - Cyclic Redundancy Check.
CSC - Clock Scheduler Card.
CiscoCell - The unit of data that is exchanged
between line cards through the switch
fabric.
FIA - Fabric Interface Asic, this Asic
resides on the line card and is
used to interface line card and
switch fabric.
ToFabFIA - Represents the ToFabric FIA, FIA
which transmits data from the
line card to the fabric.
FrFabFIA - Represents the From Fabric FIA, FIA
which receives data from the fabric.
SCA - Scheduler Control Asic, this Asic
resides on each CSC and is used to
arbitrate among the line card
requests to transmit CiscoCells
through the switch fabric.
Xbar - Crossbar Switch Asic, this Asic
resides on each fabric card and provides
the functionality of a crossbar
switch.
SLI - Serial Link interface block, this
block resides on the FIA on the line
cards and the Xbar and SCA on the
switch fabric. The functionality of SLI
is to interface the linecards and fabric
cards.
BMA - Buffer Manager Asic, this Asic is
located on a Pre OC-192 linecard.
It provides the packet buffering
and buffer queue management.
MCC - Memory Communication Controller Asic,
this Asic is located on a OC-192
linecard and is an enhanced packet buffer
Asic. MCC captures the data and control
path information for packets destined
to all line cards in the system. On the
receive side MCC interfaces with the
Rx Asic where the packets are looked up
and sent to the MCC for buffering. On the
transmit side it interfaces with the
ToFabFIA where packets arrived from MCC
will be segmented into CiscoCells before
being sent across the fabric.
CSAR - Cisco Cell Segmentation And Reassembly,
The name of an FPGA used on the RP which
handles traffic between the processor
and switch fabric.
Request - A signal sent by a FIA (on a line card)
to the SCA (on Master CSC) requesting a
switch connection to a output linecard as an
intent to transmit CiscoCells across.
Grant - A signal sent by the SCA to a FIA (on a
line card) granting a switch connection which
was requested by the FIA.
SRAM - Static Random Access Memory.
LOS - Loss Of Signal.
FPGA - Field Programmable Gate Array."REVISION"200209200000Z"DESCRIPTION"Initial version of this MIB module."::={ ciscoMgmt 281}ciscoFabricC12kMIBNotifs
OBJECTIDENTIFIER::={ ciscoFabricC12kMIB 0}ciscoFabricC12kMIBObjects
OBJECTIDENTIFIER::={ ciscoFabricC12kMIB 1}ciscoFabricC12kMIBConform
OBJECTIDENTIFIER::={ ciscoFabricC12kMIB 2}--
-- Generic information pertained to Fabric
--cfcGeneric
OBJECTIDENTIFIER::={ ciscoFabricC12kMIBObjects 1}cfcGenericGlobal
OBJECTIDENTIFIER::={ cfcGeneric 1}cfcGenericFab
OBJECTIDENTIFIER::={ cfcGeneric 2}cfcGenericSca
OBJECTIDENTIFIER::={ cfcGeneric 3}
cfcGenericXbar
OBJECTIDENTIFIER::={ cfcGeneric 4}--
-- Information pertained to Pre-OC192 Fabric
--cfcPreOc192
OBJECTIDENTIFIER::={ ciscoFabricC12kMIBObjects 2}cfcPreOc192Fab
OBJECTIDENTIFIER::={ cfcPreOc192 1}cfcPreOc192Sca
OBJECTIDENTIFIER::={ cfcPreOc192 2}cfcPreOc192Xbar
OBJECTIDENTIFIER::={ cfcPreOc192 3}--
-- Information pertained to OC192 Fabric
--cfcOc192
OBJECTIDENTIFIER::={ ciscoFabricC12kMIBObjects 3}cfcOc192Fab
OBJECTIDENTIFIER::={ cfcOc192 1}cfcOc192Sca
OBJECTIDENTIFIER::={ cfcOc192 2}cfcOc192Xbar
OBJECTIDENTIFIER::={ cfcOc192 3}--
-- Notification Enable object
--cfcNotif
OBJECTIDENTIFIER::={ ciscoFabricC12kMIBObjects 4}--
-- Textual Conventions
--CfcFabricConfigMode ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"An enumerated value that provides the current bandwidth
and redundancy configuration of the fabric.
The c12000 can have the following fabric configurations
based on the number of fabric cards present in the system.
1) Invalid configuration mode, this mode indicates that
the current fabric mode is invalid, this may be due to
insufficient number of CSC or SFC cards in the system.
2) Quarter bandwidth non-redundant mode, this mode
indicates that the bandwidth supported per slot by the
switch is 1/4 th of the full bandwidth and there is no
redundancy for the fabric failure.
3) Quarter bandwidth redundant mode, this mode indicates
that the bandwidth supported per slot by the switch is
1/4 th of the full bandwidth and there is redundancy
for the fabric failure.
4) Full bandwidth non-redundant mode, this mode indicates
that the full bandwidth is supported per slot by the
switch and there is no redundancy for the fabric
failure.
5) Full bandwidth redundant mode, this mode indicates
that the full bandwidth is supported per slot by the
switch and there is redundancy for the fabric failure.
Quarter bandwidth modes are applicable only for the systems
with pre-OC192 fabric cards."SYNTAXINTEGER{invalidMode (1),quarterBwNonRedundant (2),quarterBwRedundant (3),
fullBwNonRedundant (4),fullBwRedundant (5)}CfcFabricFiaState ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"Provides the current state of the FIA.
active - FIA is currently active.
halted - On reaching a test point for errors on FIA,
the FIA will be moved to halted state. On clearance of
the error state the FIA will be moved back to active
state."SYNTAXINTEGER{active (1),halted (2)}CfcScaInterrupts ::=TEXTUAL-CONVENTIONSTATUScurrent
DESCRIPTION"Indicates different alarm conditions in the SCA.
lossOfSync (0) -- Interrupt caused by a loss-of-sync
detection by SCA.
parityError (1) -- Interrupt caused by a request parity
error detection by SCA.
overflow (2) -- Interrupt caused by a request
overflow detection."SYNTAXBITS{lossOfSync (0),parityError (1),overflow (2)}CfcSlotMask ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"Each bit in this value is used to represent a module,
where the bit position represents the slot number of the
module.
Ex: To represent a module which is in slot 1, the bit
position 1 in the octet string is set."SYNTAXOCTETSTRING(SIZE(0..255))
--
-- Fabric Global Information
--cfcGenericGlobalFabConfigMode OBJECT-TYPESYNTAX CfcFabricConfigMode
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This object gives the current bandwidth and
redundancy configuration of fabric in the system."::={ cfcGenericGlobal 1}cfcGenericGlobalFabMasterSched OBJECT-TYPESYNTAX EntPhysicalIndexOrZero
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This object gives the entPhysicalIndex of the master
scheduler fabric card in the system. If there is no
master scheduler card then this object will return the
value zero."::={ cfcGenericGlobal 2}--
-- Switch Fabric group
----
-- Generic ToFabric FIA statistics/information
--cfcGenericFabToFabTable OBJECT-TYPESYNTAXSEQUENCEOF CfcGenericFabToFabEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table providing ToFabFIA statistics and
information in the managed system."::={ cfcGenericFab 1}cfcGenericFabToFabEntry OBJECT-TYPESYNTAX CfcGenericFabToFabEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry providing various ToFabFIA statistics and
information of the associated linecard identified
by entPhysicalIndex."INDEX{ entPhysicalIndex }::={ cfcGenericFabToFabTable 1}
CfcGenericFabToFabEntry ::=
SEQUENCE{
cfcGenericFabToFabState CfcFabricFiaState,
cfcGenericFabToFabGrantPEs Counter32,
cfcGenericFabToFabRequestPEs Counter32,
cfcGenericFabToFabCellFifoPEs Counter32}cfcGenericFabToFabState OBJECT-TYPESYNTAX CfcFabricFiaState
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates the current state of the ToFabFIA.
active - ToFabFIA is currently active.
On reaching a test point for the FIA errors, the
ToFabFIA will be moved to halted state."::={ cfcGenericFabToFabEntry 1}cfcGenericFabToFabGrantPEs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of parity errors detected by the ToFabFIA
on the grant lines to SCA."::={ cfcGenericFabToFabEntry 2}cfcGenericFabToFabRequestPEs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of parity errors detected by the ToFabFIA
on the request lines to SCA. These errors are detected
by the SCA and fed back to the ToFabFIA."::={ cfcGenericFabToFabEntry 3}cfcGenericFabToFabCellFifoPEs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of cell parity errors detected by the ToFabFIA
while dequeuing cells from the cell fifo."::={ cfcGenericFabToFabEntry 4}--
-- From Fabric FIA statistics/information
--cfcGenericFabFrFabTable OBJECT-TYPESYNTAXSEQUENCEOF CfcGenericFabFrFabEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table providing FrFabFIA information in the
managed system."::={ cfcGenericFab 2}cfcGenericFabFrFabEntry OBJECT-TYPESYNTAX CfcGenericFabFrFabEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry providing FrFabFIA information of the
associated linecard identified by entPhysicalIndex."INDEX{ entPhysicalIndex }::={ cfcGenericFabFrFabTable 1}
CfcGenericFabFrFabEntry ::=SEQUENCE{
cfcGenericFabFrFabState CfcFabricFiaState
}cfcGenericFabFrFabState OBJECT-TYPESYNTAX CfcFabricFiaState
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates the current state of the FrFabFIA.
active - FrFabFIA is currently active.
On reaching a test point for the FIA errors, the
FrFabFIA will be moved to halted state"::={ cfcGenericFabFrFabEntry 1}--
-- Per serial link information maintained by the FrFabFIA.
--cfcGenericFabFrFabSliTable OBJECT-TYPESYNTAXSEQUENCEOF CfcGenericFabFrFabSliEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table providing per serial link information maintained
by the FrFabFIA in the managed system."::={ cfcGenericFab 3}cfcGenericFabFrFabSliEntry OBJECT-TYPE
SYNTAX CfcGenericFabFrFabSliEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry providing per serial link information maintained
by the FrFabFIA on an associated linecard."INDEX{ entPhysicalIndex, cfcGenericFabFrFabSliFabIndex }::={ cfcGenericFabFrFabSliTable 1}
CfcGenericFabFrFabSliEntry ::=SEQUENCE{
cfcGenericFabFrFabSliFabIndex PhysicalIndex,
cfcGenericFabFrFabSliLOSErrors Counter32,
cfcGenericFabFrFabSliCRCErrors Counter32,
cfcGenericFabFrFabSliLOSState INTEGER}cfcGenericFabFrFabSliFabIndex OBJECT-TYPESYNTAXPhysicalIndexMAX-ACCESSnot-accessibleSTATUScurrent
DESCRIPTION"The entPhysicalIndex of the switch fabric cards (CSC/SFC)
present in the monitored system."::={ cfcGenericFabFrFabSliEntry 1}cfcGenericFabFrFabSliLOSErrors OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of LOS errors detected by the FrFabFIA
on the serial link to the fabric card identified by
cfcGenericFabFrFabSliFabIndex."::={ cfcGenericFabFrFabSliEntry 2}cfcGenericFabFrFabSliCRCErrors OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of CRC errors detected by the FrFabFIA
on the serial link to the fabric card identified by
cfcGenericFabFrFabSliFabIndex."::={ cfcGenericFabFrFabSliEntry 3}
cfcGenericFabFrFabSliLOSState OBJECT-TYPESYNTAXINTEGER{losOff (1),losOn (2)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"State of LOS detection as enabled on FrFabFIA
(identified by entPhysicalIndex) for the serial link
to the switch fabric card identified by
cfcGenericFabFrFabSliFabIndex.
Value is either,
(1) losOff
(2) losOn
A losOff state normally indicates that the FrFabFIA
has detected a state of persisting LOS on the serial
link and has disabled LOS detection for that serial
link."::={ cfcGenericFabFrFabSliEntry 4}--
-- Generic Sca statistics/information
--cfcGenericScaTable OBJECT-TYPE
SYNTAXSEQUENCEOF CfcGenericScaEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table providing SCA statistics and information in
the managed system."::={ cfcGenericSca 1}cfcGenericScaEntry OBJECT-TYPESYNTAX CfcGenericScaEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry providing various statistics and information
of SCA on an associated CSC identified by the
respective entPhysicalIndex."INDEX{ entPhysicalIndex }::={ cfcGenericScaTable 1}
CfcGenericScaEntry ::=SEQUENCE{
cfcGenericScaIdentifier SnmpAdminString,
cfcGenericScaIntrStatus CfcScaInterrupts,
cfcGenericScaIntrsEnabled CfcScaInterrupts,
cfcGenericScaConfig BITS,
cfcGenericScaPELog CfcSlotMask,
cfcGenericScaFifoOverflowLog CfcSlotMask,
cfcGenericScaLCsEnabled CfcSlotMask,
cfcGenericScaForcedBackPressure CfcSlotMask,
cfcGenericScaPreOc192LCsPresent CfcSlotMask,
cfcGenericScaOc192LCsPresent CfcSlotMask
}cfcGenericScaIdentifier OBJECT-TYPESYNTAXSnmpAdminStringMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The vendor-specific identifier string of SCA ASIC. This
identifier generally includes the revision number and the
manufacturing part number of SCA."::={ cfcGenericScaEntry 1}cfcGenericScaIntrStatus OBJECT-TYPESYNTAX CfcScaInterrupts
MAX-ACCESSread-only
STATUScurrentDESCRIPTION"Gives the status/occurrence of different alarm conditions
in the SCA. This object is a read-clear object, that is
the value of the object is cleared on every read."::={ cfcGenericScaEntry 2}cfcGenericScaIntrsEnabled OBJECT-TYPESYNTAX CfcScaInterrupts
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Gives the list of different alarm conditions enabled to
be generated by the SCA."::={ cfcGenericScaEntry 3}cfcGenericScaConfig OBJECT-TYPESYNTAXBITS{quarterBandwidth (0),halfBandwidth (1),fullBandwidth (2),
enableParity (3),priMcast (4),priUnicast (5),priAlternating (6),earlyIntrOnLOS (7),noEarlyIntrOnLOS (8),forceXbarParityXer (9),forceGrantParityXer (10),unicastAcceptMode (11),forceXbarCrcOnCtlLink0 (12),forceXbarCrcOnCtlLink1 (13),forceXbarCrcOnCtlLink2 (14),
forceXbarCrcOnCtlLink3 (15)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Gives the current configuration of the SCA ASIC.
quarterBandwidth (0) -- 1/4th of the full bandwidth
is supported per slot by
the switch.
halfBandwidth (1) -- 1/2th of the full bandwidth
is supported per slot by
the switch.
fullBandwidth (2) -- Full bandwidth is supported
per slot by the switch.
enableParity (3) -- Parity handling by SCA is
enabled.
priMcast (4) -- Priority of Multicast
requests is greater then
Unicast requests.
priUnicast (5) -- Priority of Unicast
requests is greater then
Multicast requests.
priAlternating (6) -- Alternate the priority
between pri-mcast and
pri-unicast modes every
cell clock.
earlyIntrOnLOS (7) -- Cause early interrupt on
loss-of-sync error.
noEarlyIntrOnLOS (8) -- Allow time to resync on
loss-of-sync error.
forceXbarParityXer (9) -- Force bad parity on xbar
on every cell clock.
forceGrantParityXer (10) -- Force bad partity on grant
to every line card.
unicastAcceptMode (11) -- Enable unicast accept
pointer updating only on
cell periods when Unicast
has higher priority over
multicast.
forceXbarCrcOnCtlLink0 (12)-- Force CRC error on Xbar
control link 0.
forceXbarCrcOnCtlLink0 (13)-- Force CRC error on Xbar
control link 1.
forceXbarCrcOnCtlLink0 (14)-- Force CRC error on Xbar
control link 2.
forceXbarCrcOnCtlLink0 (15)-- Force CRC error on Xbar
control link 3."
::={ cfcGenericScaEntry 4}cfcGenericScaPELog OBJECT-TYPESYNTAX CfcSlotMask
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates the modules which caused the parity error and
resulted in an interrupt. The corresponding bit is set on
occurrence of parity error for a module. This object is a
read-clear object, that is the value of the object is
cleared on every read."::={ cfcGenericScaEntry 5}cfcGenericScaFifoOverflowLog OBJECT-TYPESYNTAX CfcSlotMask
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates the modules which caused an overflow at the
request fifo and resulted in an interrupt. The
corresponding bit is set on occurrence of fifo overflow
for a module. This object is a read-clear object, that is
the value of the object is cleared on every read."
::={ cfcGenericScaEntry 6}cfcGenericScaLCsEnabled OBJECT-TYPESYNTAX CfcSlotMask
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates the modules which are present and the SCA has
been configured to start accepting requests from this
module."::={ cfcGenericScaEntry 7}cfcGenericScaForcedBackPressure OBJECT-TYPESYNTAX CfcSlotMask
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates the linecards which exerted backpressure.
SCA will not grant Xbar connection to these linecards."::={ cfcGenericScaEntry 8}cfcGenericScaOc192LCsPresent OBJECT-TYPESYNTAX CfcSlotMask
MAX-ACCESSread-only
STATUScurrentDESCRIPTION"Indicates the OC192 linecards present in the monitored
system. The corresponding bit is set for each linecard
present, indicating the postion."::={ cfcGenericScaEntry 9}cfcGenericScaPreOc192LCsPresent OBJECT-TYPESYNTAX CfcSlotMask
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates the Pre-OC192 linecards present in the
monitored system. The corresponding bit is set for
each linecard present, indicating the position."::={ cfcGenericScaEntry 10}--
-- Generic Xbar information
--cfcGenericXbarTable OBJECT-TYPESYNTAXSEQUENCEOF CfcGenericXbarEntry
MAX-ACCESSnot-accessibleSTATUScurrent
DESCRIPTION"A table providing Xbar information in the
managed system."::={ cfcGenericXbar 1}cfcGenericXbarEntry OBJECT-TYPESYNTAX CfcGenericXbarEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry providing Xbar information on an associated
fabric card identified by entPhysicalIndex."INDEX{ entPhysicalIndex }::={ cfcGenericXbarTable 1}
CfcGenericXbarEntry ::=SEQUENCE{
cfcGenericXbarIdentifier SnmpAdminString}cfcGenericXbarIdentifier OBJECT-TYPESYNTAXSnmpAdminStringMAX-ACCESSread-onlySTATUScurrentDESCRIPTION
"The vendor-specific identifier string of Xbar ASIC. This
identifier generally includes the revision number and the
manufacturing part number of Xbar."::={ cfcGenericXbarEntry 1}--
-- Pre-OC192 Group
----
-- Pre-OC192 Fabric information
--cfcPreOc192FabToFabTable OBJECT-TYPESYNTAXSEQUENCEOF CfcPreOc192FabToFabEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table providing pre-OC192 ToFabFIA statistics and
information in the managed system."::={ cfcPreOc192Fab 1}cfcPreOc192FabToFabEntry OBJECT-TYPESYNTAX CfcPreOc192FabToFabEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry providing various statistics and
counters of pre-OC192 ToFabFIA on an associated
linecard identified by entPhysicalIndex."INDEX{ entPhysicalIndex }::={ cfcPreOc192FabToFabTable 1}
CfcPreOc192FabToFabEntry ::=SEQUENCE{
cfcPreOc192FabToFabScaLosts Counter32,
cfcPreOc192FabToFabUCFifoOvFlws Counter32,
cfcPreOc192FabToFabUCFifoUnFlws Counter32,
cfcPreOc192FabToFabMCFifoErrs Counter32,
cfcPreOc192FabToFabBmaPEs Counter32,
cfcPreOc192FabToFabBmaHskErrs Counter32,
cfcPreOc192FabToFabUniDestMCRqs Counter32,
cfcPreOc192FabToFabMultiDstUCRqs Counter32,
cfcPreOc192FabToFabEmptyDestRqs Counter32}cfcPreOc192FabToFabScaLosts OBJECT-TYPESYNTAXCounter32
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates the number of times the ToFabFIA lost contact
with SCA(scheduler controller Asic) on master CSC."::={ cfcPreOc192FabToFabEntry 1}cfcPreOc192FabToFabUCFifoOvFlws OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of unicast fifo overflow errors on the ToFabFIA.
Problems between BMA/CSAR and the ToFabFIA may be one
of the reasons for these errors."::={ cfcPreOc192FabToFabEntry 2}cfcPreOc192FabToFabUCFifoUnFlws OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of unicast fifo underflow errors on the ToFabFIA.
These errors are caused by the SCA granting without
actually getting a request from the ToFabFIA."::={ cfcPreOc192FabToFabEntry 3}cfcPreOc192FabToFabMCFifoErrs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of multicast fifo overflow and underflow errors
on the ToFabFIA. Problems between BMA/CSAR and the
ToFabFIA may be one of the reasons for multicast fifo
overflow errors. Underflow errors are caused by the SCA
granting without actually getting a request from the
ToFabFIA."::={ cfcPreOc192FabToFabEntry 4}cfcPreOc192FabToFabBmaPEs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of parity errors on cells received from BMA by the
ToFabFIA."::={ cfcPreOc192FabToFabEntry 5}cfcPreOc192FabToFabBmaHskErrs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of handshake errors between the BMA/CSAR and the
ToFabFIA."::={ cfcPreOc192FabToFabEntry 6}cfcPreOc192FabToFabUniDestMCRqs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of requests with single destination in a multicast
request detected by ToFabFIA. The FIA will send this
cell to the destination."::={ cfcPreOc192FabToFabEntry 7}cfcPreOc192FabToFabMultiDstUCRqs OBJECT-TYPESYNTAXCounter32
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of requests with multiple destinations in a unicast
request detected by a ToFabFIA. The FIA will drop this
cell."::={ cfcPreOc192FabToFabEntry 8}cfcPreOc192FabToFabEmptyDestRqs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of requests with empty destination detected by
ToFabFIA. The FIA will drop this cell."::={ cfcPreOc192FabToFabEntry 9}--
-- From Fabric PreOC192 FIA statistics/information
--cfcPreOc192FabFrFabTable OBJECT-TYPESYNTAXSEQUENCEOF CfcPreOc192FabFrFabEntry
MAX-ACCESSnot-accessibleSTATUScurrent
DESCRIPTION"A table providing pre-OC192 FrFabFIA statistics and
information in the managed system."::={ cfcPreOc192Fab 2}cfcPreOc192FabFrFabEntry OBJECT-TYPESYNTAX CfcPreOc192FabFrFabEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry providing various statistics and information
of pre-OC192 FrFabFIA on an associated linecard
identified by entPhysicalIndex."INDEX{ entPhysicalIndex }::={ cfcPreOc192FabFrFabTable 1}
CfcPreOc192FabFrFabEntry ::=SEQUENCE{
cfcPreOc192FabFrFabCellFifoPEs Counter32,
cfcPreOc192FabFrFabRedFifoPEs Counter32,
cfcPreOc192FabFrFabRedFifoOvflws Counter32,
cfcPreOc192FabFrFabCellDrops Counter32
}cfcPreOc192FabFrFabCellFifoPEs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of cisco cell fifo parity errors detected by the
FrFabFIA while dequeuing cells from the cell fifo."::={ cfcPreOc192FabFrFabEntry 1}cfcPreOc192FabFrFabRedFifoPEs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of redundant data fifo parity errors detected by
the FrFabFIA."::={ cfcPreOc192FabFrFabEntry 2}cfcPreOc192FabFrFabRedFifoOvflws OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-only
STATUScurrentDESCRIPTION"Count of redundant data fifo overflow errors detected by
the FrFabFIA. This is caused if the back pressure
is broken (i.e. the FrFabFIA exerts back pressure and the
SCA keeps giving more data to it)."::={ cfcPreOc192FabFrFabEntry 3}cfcPreOc192FabFrFabCellDrops OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of number of cells dropped by the FrFabFIA.
In case of non-redundant fabric configuration, cell drops
can occur when a parity error is detected on one or more
than one serial link. In case of redundant fabric
configuration cell drops can occur when a cell gets
corrupted on more than one serial link."::={ cfcPreOc192FabFrFabEntry 4}--
-- Pre Oc192 SCA Information
--cfcPreOc192ScaTable OBJECT-TYPESYNTAXSEQUENCEOF CfcPreOc192ScaEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table providing pre-OC192 SCA statistics and
information in the managed system."::={ cfcPreOc192Sca 1}cfcPreOc192ScaEntry OBJECT-TYPESYNTAX CfcPreOc192ScaEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry providing various statistics and information
of pre-OC192 SCA on an associated CSC identified by
entPhysicalIndex."INDEX{ entPhysicalIndex }::={ cfcPreOc192ScaTable 1}
CfcPreOc192ScaEntry ::=SEQUENCE{
cfcPreOc192ScaReSyncDelay Unsigned32,
cfcPreOc192ScaLOSLog CfcSlotMask
}cfcPreOc192ScaReSyncDelay OBJECT-TYPESYNTAXUnsigned32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of cell periods that the SCA will allow
the serial links connected to a module and Xbar to be
resynced, if a loss-of-sync has occurred on the
corresponding module. The value '0' indicates that on
occurrence of LOS, the sca will only log the LOS event
and do the scheduling for that module as normal."::={ cfcPreOc192ScaEntry 1}cfcPreOc192ScaLOSLog OBJECT-TYPESYNTAX CfcSlotMask
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates the LOS event occurrence on each linecard
connected to this CSC. The corresponding bit is set on
occurrence of LOS event on a line card. This object is
a read-clear object, that is the value of the object is
cleared on every read."::={ cfcPreOc192ScaEntry 2}
--
-- Pre-Oc192 Xbar information
--cfcPreOc192XbarTable OBJECT-TYPESYNTAXSEQUENCEOF CfcPreOc192XbarEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table providing Pre-OC192 Xbar statistics and
information in the managed system."::={ cfcPreOc192Xbar 1}cfcPreOc192XbarEntry OBJECT-TYPESYNTAX CfcPreOc192XbarEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry providing various statistics and information
of Pre-OC192 Xbar on an associated fabric card identified
by entPhysicalIndex."INDEX{ entPhysicalIndex }::={ cfcPreOc192XbarTable 1}
CfcPreOc192XbarEntry ::=SEQUENCE{
cfcPreOc192XbarIntrStatus BITS,
cfcPreOc192XbarParityChkStatus TruthValue}cfcPreOc192XbarIntrStatus OBJECT-TYPESYNTAXBITS{frameLossOfSync(0),parityErrorFromSca(1)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates the occurrence of different alarm conditions in
Xbar. This object is a read-clear object, that is the
value of the object is cleared on every read."::={ cfcPreOc192XbarEntry 1}cfcPreOc192XbarParityChkStatus OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-only
STATUScurrentDESCRIPTION"Indicates the parity check state in control data received
from SCA to the Xbar.
true(1) indicates that the parity check is enabled.
false(2) indicates that the parity check is disabled."::={ cfcPreOc192XbarEntry 2}--
-- Oc192 Fabric information/statistics
--cfcOc192FabToFabTable OBJECT-TYPESYNTAXSEQUENCEOF CfcOc192FabToFabEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table providing OC192 ToFabFIA statistics
and information in the managed system."::={ cfcOc192Fab 1}cfcOc192FabToFabEntry OBJECT-TYPESYNTAX CfcOc192FabToFabEntry
MAX-ACCESSnot-accessibleSTATUScurrent
DESCRIPTION"An entry providing various statistics and information
of OC192 ToFabFIA on an associated linecard identified
by entPhysicalIndex."INDEX{ entPhysicalIndex }::={ cfcOc192FabToFabTable 1}
CfcOc192FabToFabEntry ::=SEQUENCE{
cfcOc192FabToFabMccDataPEs Counter32,
cfcOc192FabToFabMccCmdPEs Counter32,
cfcOc192FabToFabBackPressurePEs Counter32,
cfcOc192FabToFabCellFifoOvFlws Counter32,
cfcOc192FabToFabCellFifoUnFlws Counter32,
cfcOc192FabToFabMccCmdSeqEndErrs Counter32,
cfcOc192FabToFabMccCmdSeqStrErrs Counter32}cfcOc192FabToFabMccDataPEs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-only
STATUScurrentDESCRIPTION"Count of the parity errors on data lines from
MCC to ToFabFIA. This error would cause the
ToFabFIA to halt."::={ cfcOc192FabToFabEntry 1}cfcOc192FabToFabMccCmdPEs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of the parity errors on command lines from
MCC to ToFabFIA. This error would cause the
ToFabFIA to halt."::={ cfcOc192FabToFabEntry 2}cfcOc192FabToFabBackPressurePEs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of the parity errors on back pressure line from
FrFabFIA to ToFabFIA. This error would cause the
ToFabFIA to halt."::={ cfcOc192FabToFabEntry 3}cfcOc192FabToFabCellFifoOvFlws OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of the cell fifo overflow errors detected by the
ToFabFIA. This error would cause the ToFabFIA to halt."::={ cfcOc192FabToFabEntry 4}cfcOc192FabToFabCellFifoUnFlws OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of the cell fifo underflow errors detected by the
ToFabFIA. This error would cause the ToFabFIA to halt."::={ cfcOc192FabToFabEntry 5}cfcOc192FabToFabMccCmdSeqEndErrs OBJECT-TYPESYNTAXCounter32
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of the illegal sequence of command errors where
a middle or start command followed by a start command
is received from MCC."::={ cfcOc192FabToFabEntry 6}cfcOc192FabToFabMccCmdSeqStrErrs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of the illegal sequence of command errors where
an end command followed by an end or middle command
is received from MCC."::={ cfcOc192FabToFabEntry 7}--
-- OC192 From Fabric FIA information
--cfcOc192FabFrFabTable OBJECT-TYPESYNTAXSEQUENCEOF CfcOc192FabFrFabEntry
MAX-ACCESSnot-accessible
STATUScurrentDESCRIPTION"A table providing FrFabFIA statistics and
information in the managed system."::={ cfcOc192Fab 2}cfcOc192FabFrFabEntry OBJECT-TYPESYNTAX CfcOc192FabFrFabEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry providing various statistics and information
of OC192 FrFabFIA on an associated linecard identified
by entPhysicalIndex."INDEX{ entPhysicalIndex }::={ cfcOc192FabFrFabTable 1}
CfcOc192FabFrFabEntry ::=SEQUENCE{
cfcOc192FabFrFabPktLenErrs Counter32,
cfcOc192FabFrFabExtRamPEs Counter32,
cfcOc192FabFrFabPktLenPEs Counter32,
cfcOc192FabFrFabHdrSramPEs Counter32,
cfcOc192FabFrFabTxCtrlPEs Counter32,
cfcOc192FabFrFabHdrFifoOvFlws Counter32,
cfcOc192FabFrFabExtSramOvFlws Counter32,
cfcOc192FabFrFabFirstLastErrs Counter32,
cfcOc192FabFrFabSeqErrs Counter32}cfcOc192FabFrFabPktLenErrs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of the packets (after reassembly from Cisco
cells) which exceed the maximum permitted packet
length of FrFabFIA. These packets will be dropped."::={ cfcOc192FabFrFabEntry 1}cfcOc192FabFrFabExtRamPEs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"Count of the parity errors detected in FrFabFIA's
external SRAM."::={ cfcOc192FabFrFabEntry 2}cfcOc192FabFrFabPktLenPEs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of the parity errors detected in payload packet
length field of the FrFabFIA's Payload Header SRAM."::={ cfcOc192FabFrFabEntry 3}cfcOc192FabFrFabHdrSramPEs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of the parity errors detected in payload header
field of the FrFabFIA's Payload Header SRAM."::={ cfcOc192FabFrFabEntry 4}
cfcOc192FabFrFabTxCtrlPEs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of the parity errors detected on the Tx control
bits of FrFabFIA."::={ cfcOc192FabFrFabEntry 5}cfcOc192FabFrFabHdrFifoOvFlws OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of the overflow errors in the FrFabFIA's reassembly
fifos in the on-chip payload header SRAM."::={ cfcOc192FabFrFabEntry 6}cfcOc192FabFrFabExtSramOvFlws OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"Count of the overflow errors in the FrFabFIA's reassembly
external SRAM's payload fifos."::={ cfcOc192FabFrFabEntry 7}cfcOc192FabFrFabFirstLastErrs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of the First-Last errors detected by FrFabFIA's.
If a first cell is received for a reassembly fifo, while
an earlier packet in the same reassembly fifo is still
waiting for its last cell, then it is called a First-Last
Error."::={ cfcOc192FabFrFabEntry 8}cfcOc192FabFrFabSeqErrs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of the sequence errors detected by FrFabFIA in
the cells received for reassembly. If a cell is received
whose sequence number is not an unit increment from the
previous cell of the same packet then it is a sequence
error."::={ cfcOc192FabFrFabEntry 9}--
-- Oc192 SLI Table
--cfcOc192FabFrFabSliTable OBJECT-TYPESYNTAXSEQUENCEOF CfcOc192FabFrFabSliEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table providing per serial link information maintained
by the OC192 FrFabFIA in the managed system."::={ cfcOc192Fab 3}cfcOc192FabFrFabSliEntry OBJECT-TYPESYNTAX CfcOc192FabFrFabSliEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry providing per serial link information maintained
by the OC192 FrFabFIA on an associated linecard identified
by entPhysicalIndex."INDEX{ entPhysicalIndex, cfcOc192FabFrFabSliSwitchIndex }::={ cfcOc192FabFrFabSliTable 1}
CfcOc192FabFrFabSliEntry ::=SEQUENCE{
cfcOc192FabFrFabSliSwitchIndex PhysicalIndex,
cfcOc192FabFrFabSliXorErrs Counter32,
cfcOc192FabFrFabSliCellDrops Counter32}cfcOc192FabFrFabSliSwitchIndex OBJECT-TYPESYNTAXPhysicalIndexMAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The entPhysicalIndex of the switch fabric cards (CSC/SFC)
present in the monitored system."::={ cfcOc192FabFrFabSliEntry 1}cfcOc192FabFrFabSliXorErrs OBJECT-TYPESYNTAXCounter32
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of the XOR check errors detected by FrFabFIA
reassembly. The data paths are horizontally XORed and
the result is expected to match the contents of the
redundant path else it is counted as XOR error, this
error applies only in redundant mode of fabric."::={ cfcOc192FabFrFabSliEntry 2}cfcOc192FabFrFabSliCellDrops OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of the total cells dropped by the FrFabFIA from
the fabric card due to uncorrectable errors. Uncorrectable
errors are the errors other than CRC, LOS, Horizontal XOR
and idle cell which cannot be corrected."::={ cfcOc192FabFrFabSliEntry 3}--
-- Per LC stats maintained in FrFabFIA
--cfcOc192FabFrFabStatTable OBJECT-TYPE
SYNTAXSEQUENCEOF CfcOc192FabFrFabStatEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table providing per module statistics information
maintained by the OC192 FrFabFIA in the managed system."::={ cfcOc192Fab 4}cfcOc192FabFrFabStatEntry OBJECT-TYPESYNTAX CfcOc192FabFrFabStatEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry providing per module statistics information
maintained by the OC192 FrFabFIA on an associated
linecard identified by entPhysicalIndex."INDEX{ entPhysicalIndex, cfcOc192FabFrFabStatLCIndex }::={ cfcOc192FabFrFabStatTable 1}
CfcOc192FabFrFabStatEntry ::=SEQUENCE{
cfcOc192FabFrFabStatLCIndex PhysicalIndex,
cfcOc192FabFrFabStatUCHiPktDrops Counter32,
cfcOc192FabFrFabStatUCLoPktDrops Counter32,
cfcOc192FabFrFabStatMCHiPktDrops Counter32,
cfcOc192FabFrFabStatMCLoPktDrops Counter32}cfcOc192FabFrFabStatLCIndex OBJECT-TYPESYNTAXPhysicalIndexMAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The entPhysicalIndex of the Line card present in the
monitored system."::={ cfcOc192FabFrFabStatEntry 1}cfcOc192FabFrFabStatUCHiPktDrops OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of Unicast high priority packets dropped, from
source module indicated by cfcOc192FabFrFabStatLCIndex."::={ cfcOc192FabFrFabStatEntry 2}cfcOc192FabFrFabStatUCLoPktDrops OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of Unicast low priority packets dropped, from
source module indicated by cfcOc192FabFrFabStatLCIndex."::={ cfcOc192FabFrFabStatEntry 3}cfcOc192FabFrFabStatMCHiPktDrops OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of Multicast high priority packets dropped, from
source module indicated by cfcOc192FabFrFabStatLCIndex."::={ cfcOc192FabFrFabStatEntry 4}cfcOc192FabFrFabStatMCLoPktDrops OBJECT-TYPE
SYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Count of Multicast low priority packets dropped, from
source module indicated by cfcOc192FabFrFabStatLCIndex."::={ cfcOc192FabFrFabStatEntry 5}--
-- Oc192 SCA Information
--cfcOc192ScaTable OBJECT-TYPESYNTAXSEQUENCEOF CfcOc192ScaEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table providing OC192 SCA statistics and information in
the managed system."::={ cfcOc192Sca 1}cfcOc192ScaEntry OBJECT-TYPESYNTAX CfcOc192ScaEntry
MAX-ACCESSnot-accessibleSTATUScurrent
DESCRIPTION"An entry providing various statistics and information
of OC192 SCA on an associated CSC identified by
entPhysicalIndex."INDEX{ entPhysicalIndex }::={ cfcOc192ScaTable 1}
CfcOc192ScaEntry ::=SEQUENCE{
cfcOc192ScaRotationPeriod Unsigned32,
cfcOc192ScaDisableGrants CfcSlotMask
}cfcOc192ScaRotationPeriod OBJECT-TYPESYNTAXUnsigned32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Determines the period of rotating the priority between
Unicast and Multicast, in cell periods, when the SCA is
configured with alternating priority mode.
For example, if the value of this object is 63 then
the priority will change every 64 cell periods, if the
value is 0 then the priority will change every cell
period."
::={ cfcOc192ScaEntry 1}cfcOc192ScaDisableGrants OBJECT-TYPESYNTAX CfcSlotMask
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates the disable of grants by SCA to any requests
coming from a specific module. The corresponding bit
is set for each module."::={ cfcOc192ScaEntry 2}--
-- Oc192 Xbar information
--cfcOc192XbarTable OBJECT-TYPESYNTAXSEQUENCEOF CfcOc192XbarEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table providing OC192 Xbar statistics and information
in the managed system."::={ cfcOc192Xbar 1}cfcOc192XbarEntry OBJECT-TYPESYNTAX CfcOc192XbarEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry providing various statistics and information
of OC192 Xbar on an associated fabric card identified
by entPhysicalIndex."INDEX{ entPhysicalIndex }::={ cfcOc192XbarTable 1}
CfcOc192XbarEntry ::=SEQUENCE{
cfcOc192XbarCtrlLOSStatus BITS,
cfcOc192XbarCtrlCRCErr BITS}cfcOc192XbarCtrlLOSStatus OBJECT-TYPESYNTAXBITS{frameLosErr (0),sliErrorOnControlLink0 (1),sliErrorOnControlLink1 (2),
sliErrorOnControlLink2 (3),sliErrorOnControlLink3 (4)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates the occurrence of LOS errors on the control path
of Xbar.
frameLosErr (0) -- Frame LOS error.
sliErrorOnControlLink0 (1) -- LOS detected on SLI
control link 0.
sliErrorOnControlLink1 (2) -- LOS detected on SLI
control link 1.
sliErrorOnControlLink2 (3) -- LOS detected on SLI
control link 2.
sliErrorOnControlLink3 (4) -- LOS detected on SLI
control link 3.
This object is a read-clear object, that is the value
of the object is cleared on every read."::={ cfcOc192XbarEntry 1}cfcOc192XbarCtrlCRCErr OBJECT-TYPE
SYNTAXBITS{ctlCrcErrorLink0 (0),ctlCrcErrorLink1 (1),ctlCrcErrorLink2 (2),ctlCrcErrorLink3 (3)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates the occurrence of CRC error on any of the
four control links. This object is a read-clear object,
that is the value of the object is cleared on every read."::={ cfcOc192XbarEntry 2}-- Notification Enable objectcfcNotifEnable OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-writeSTATUScurrent
DESCRIPTION"This variable indicates whether the system
produces the notifications defined in the MIB.
A false value will prevent the notifications in
the MIB from being generated by the system."DEFVAL{ false }::={ cfcNotif 1}-- NotificationciscoFabricC12kMIBFabMasterSchCh NOTIFICATION-TYPEOBJECTS{
cfcGenericGlobalFabMasterSched,
entPhysicalName
}STATUScurrentDESCRIPTION"This notification is generated when master scheduler
on the system changes. It typically indicates the
switchover of the scheduler card.
cfcGenericGlobalFabMasterSched represents the
entPhysicalIndex of the new master scheduler card,
while entPhysicalName represents the entity physical
name of the card. The case of all scheduler cards going
down would be represented by a value 0 for the
cfcGenericGlobalFabMasterSched and noSuchInstance for the
entPhysicalName."
::={ ciscoFabricC12kMIBNotifs 1}-- conformance informationciscoFabricC12kMIBCompliances OBJECTIDENTIFIER::={ ciscoFabricC12kMIBConform 1}ciscoFabricC12kMIBGroups OBJECTIDENTIFIER::={ ciscoFabricC12kMIBConform 2}-- Compliances statementciscoFabricC12kMIBCompliance MODULE-COMPLIANCESTATUScurrentDESCRIPTION"The compliance statement for entities which implement
the CISCO-FABRIC-C12K-MIB."MODULE-- this moduleMANDATORY-GROUPS{
ciscoFabricC12kGlobalGroup,
ciscoFabricC12kFiaGroup,
ciscoFabricC12kScaGroup,
ciscoFabricC12kXbarGroup,
ciscoFabricC12kPreOc192FiaGroup,
ciscoFabricC12kNotifEnableGroup,
ciscoFabricC12kNotifGroup
}GROUP ciscoFabricC12kPreOc192ScaGroup
DESCRIPTION"This group is mandatory only if PreOC192 clock scheduler
cards are present in the managed system"GROUP ciscoFabricC12kPreOc192XbarGroup
DESCRIPTION"This group is mandatory only if PreOC192 fabric cards
are present in the managed system"GROUP ciscoFabricC12kOc192FiaGroup
DESCRIPTION"This group is mandatory only if OC192 line cards are
supported in the managed system"GROUP ciscoFabricC12kOc192LCGroup
DESCRIPTION"This group is mandatory only if OC192 line cards are
supported in the managed system"GROUP ciscoFabricC12kOc192ScaGroup
DESCRIPTION"This group is mandatory only if OC192 clock scheduler
cards are present in the managed system"GROUP ciscoFabricC12kOc192XbarGroup
DESCRIPTION"This group is mandatory only if OC192 fabric cards
are present in the managed system"::={ ciscoFabricC12kMIBCompliances 1}-- units of compliancesciscoFabricC12kGlobalGroup OBJECT-GROUPOBJECTS{
cfcGenericGlobalFabConfigMode,
cfcGenericGlobalFabMasterSched
}STATUScurrentDESCRIPTION"A collection of Global fabric configuration
objects."::={ ciscoFabricC12kMIBGroups 1}ciscoFabricC12kFiaGroup OBJECT-GROUPOBJECTS{
cfcGenericFabToFabState,
cfcGenericFabToFabGrantPEs,
cfcGenericFabToFabRequestPEs,
cfcGenericFabToFabCellFifoPEs,
cfcGenericFabFrFabState,
cfcGenericFabFrFabSliLOSErrors,
cfcGenericFabFrFabSliCRCErrors,
cfcGenericFabFrFabSliLOSState
}STATUScurrentDESCRIPTION"A collection of generic FIA status and statistics
objects."::={ ciscoFabricC12kMIBGroups 2}ciscoFabricC12kScaGroup OBJECT-GROUPOBJECTS{
cfcGenericScaIdentifier,
cfcGenericScaIntrStatus,
cfcGenericScaIntrsEnabled,
cfcGenericScaConfig,
cfcGenericScaPELog,
cfcGenericScaFifoOverflowLog,
cfcGenericScaLCsEnabled,
cfcGenericScaForcedBackPressure,
cfcGenericScaPreOc192LCsPresent
}STATUScurrentDESCRIPTION"A collection of generic SCA status objects."::={ ciscoFabricC12kMIBGroups 3}
ciscoFabricC12kXbarGroup OBJECT-GROUPOBJECTS{
cfcGenericXbarIdentifier
}STATUScurrentDESCRIPTION"A collection of generic Xbar status objects."::={ ciscoFabricC12kMIBGroups 4}ciscoFabricC12kPreOc192FiaGroup OBJECT-GROUPOBJECTS{
cfcPreOc192FabToFabScaLosts,
cfcPreOc192FabToFabUCFifoOvFlws,
cfcPreOc192FabToFabUCFifoUnFlws,
cfcPreOc192FabToFabMCFifoErrs,
cfcPreOc192FabToFabBmaPEs,
cfcPreOc192FabToFabBmaHskErrs,
cfcPreOc192FabToFabUniDestMCRqs,
cfcPreOc192FabToFabMultiDstUCRqs,
cfcPreOc192FabToFabEmptyDestRqs,
cfcPreOc192FabFrFabCellFifoPEs,
cfcPreOc192FabFrFabRedFifoPEs,
cfcPreOc192FabFrFabRedFifoOvflws,
cfcPreOc192FabFrFabCellDrops
}STATUScurrentDESCRIPTION"A collection of pre-OC192 FIA status and statistics
objects."::={ ciscoFabricC12kMIBGroups 5}ciscoFabricC12kPreOc192ScaGroup OBJECT-GROUPOBJECTS{
cfcPreOc192ScaReSyncDelay,
cfcPreOc192ScaLOSLog
}STATUScurrentDESCRIPTION"A collection of Pre-OC192 SCA status objects."::={ ciscoFabricC12kMIBGroups 6}ciscoFabricC12kPreOc192XbarGroup OBJECT-GROUPOBJECTS{
cfcPreOc192XbarIntrStatus,
cfcPreOc192XbarParityChkStatus
}STATUScurrentDESCRIPTION"A collection of Pre-Oc192 Xbar status objects."
::={ ciscoFabricC12kMIBGroups 7}ciscoFabricC12kOc192FiaGroup OBJECT-GROUPOBJECTS{
cfcOc192FabToFabMccDataPEs,
cfcOc192FabToFabMccCmdPEs,
cfcOc192FabToFabBackPressurePEs,
cfcOc192FabToFabCellFifoOvFlws,
cfcOc192FabToFabCellFifoUnFlws,
cfcOc192FabToFabMccCmdSeqEndErrs,
cfcOc192FabToFabMccCmdSeqStrErrs,
cfcOc192FabFrFabPktLenErrs,
cfcOc192FabFrFabExtRamPEs,
cfcOc192FabFrFabPktLenPEs,
cfcOc192FabFrFabHdrSramPEs,
cfcOc192FabFrFabTxCtrlPEs,
cfcOc192FabFrFabHdrFifoOvFlws,
cfcOc192FabFrFabExtSramOvFlws,
cfcOc192FabFrFabFirstLastErrs,
cfcOc192FabFrFabSeqErrs,
cfcOc192FabFrFabSliXorErrs,
cfcOc192FabFrFabSliCellDrops,
cfcOc192FabFrFabStatUCHiPktDrops,
cfcOc192FabFrFabStatUCLoPktDrops,
cfcOc192FabFrFabStatMCHiPktDrops,
cfcOc192FabFrFabStatMCLoPktDrops
}STATUScurrentDESCRIPTION"A collection of OC192 FIA status and statistics
objects."::={ ciscoFabricC12kMIBGroups 8}ciscoFabricC12kOc192LCGroup OBJECT-GROUPOBJECTS{
cfcGenericScaOc192LCsPresent
}STATUScurrentDESCRIPTION"A collection of OC192 linecard generic objects."::={ ciscoFabricC12kMIBGroups 9}ciscoFabricC12kOc192ScaGroup OBJECT-GROUPOBJECTS{
cfcOc192ScaRotationPeriod,
cfcOc192ScaDisableGrants
}STATUScurrent
DESCRIPTION"A collection of OC192 SCA status objects."::={ ciscoFabricC12kMIBGroups 10}ciscoFabricC12kOc192XbarGroup OBJECT-GROUPOBJECTS{
cfcOc192XbarCtrlLOSStatus,
cfcOc192XbarCtrlCRCErr
}STATUScurrentDESCRIPTION"A collection of OC192 Xbar status objects."::={ ciscoFabricC12kMIBGroups 11}ciscoFabricC12kNotifEnableGroup OBJECT-GROUPOBJECTS{
cfcNotifEnable
}STATUScurrentDESCRIPTION"The collection of objects which are used to
control generation of notification."::={ ciscoFabricC12kMIBGroups 12}ciscoFabricC12kNotifGroup NOTIFICATION-GROUP
NOTIFICATIONS{
ciscoFabricC12kMIBFabMasterSchCh
}STATUScurrentDESCRIPTION"A collection of notifications generated by
the devices supporting this MIB."::={ ciscoFabricC12kMIBGroups 13}END